Volume 10, Issue 1 (spring 2006)                   jwss 2006, 10(1): 15-28 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

A. Keshavarzi, M. J. Kazemzadeh Parsi. Experimental Study of Turbulent Flow Structure, Separation Zone and Comparison with Turbulence Models at 45 Degree Closed-end Water Intake. jwss 2006; 10 (1) :15-28
URL: http://jstnar.iut.ac.ir/article-1-520-en.html
Abstract:   (17193 Views)
Flow structure at water intake is very complicated and three-dimensional. Due to this the application of one and two-dimensional equations can not sufficiently explain the flow structure at water intake. In this study, the simulation of flow structure at a 45 degree water intake was investigated numerically and experimentally. Here, the characteristic of separation zone and velocity distribution at 45 degree water intake were investigated using Standard k-ε and RNG k-ε models. It was found that the Standard k-ε model enables to estimate the flow and separation zone at water intake. Also, the location of separate zone at the inlet of water intake was studied using experimental and numerical approach. It was found that the separation zone at 45 degree water intake occurs at the downstream of the inlet.
Full-Text [PDF 547 kb]   (3092 Downloads)    
Type of Study: Research | Subject: Ggeneral
Received: 2008/01/9 | Published: 2006/04/15

Add your comments about this article : Your username or Email:
CAPTCHA

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 CC BY-NC 4.0 | JWSS - Isfahan University of Technology

Designed & Developed by : Yektaweb