<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Water and Soil Science</title>
<title_fa>علوم آب و خاک</title_fa>
<short_title>jwss</short_title>
<subject>Agriculture</subject>
<web_url>http://jstnar.iut.ac.ir</web_url>
<journal_hbi_system_id>0</journal_hbi_system_id>
<journal_hbi_system_user>user</journal_hbi_system_user>
<journal_id_issn>2476-3594</journal_id_issn>
<journal_id_issn_online>2476-5554</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.47176/jwss</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1391</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2012</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<volume>16</volume>
<number>60</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>تعیین معادله فشار ورودی به لوله‌های فرعی آبیاری بارانی با در نظر گرفتن دبی متفاوت برای آبپاش‌ها</title_fa>
	<title>Calculating Inlet Pressure for Multi-Outlet Horizontal Irrigation Laterals Considering Variable Outflow in Outlets</title>
	<subject_fa>عمومی</subject_fa>
	<subject>Ggeneral</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>محاسبه دقیق میزان فشار ورودی به لوله‌های آبیاری بارانی مسئله‌ای مهم برای برخورداری سیستم از توزیع یکنواختی مناسب می‌باشد. فاکتور متوسط ضریب تصحیح اصلاح شده FaAVG امکان محاسبه فشار ورودی به لوله را هنگامی که اولین آبپاش به فاصله دلخواه از ابتدای لوله قرار گرفته باشد فراهم می‌کند. در این مطالعه، به منظور بررسی اثر افت فشار مجاز در طول لوله فرعی بر میزان فشار ورودی به لوله، معادله‌ای جدید برای محاسبه این ضریب ارائه شد. برای نیل به این هدف و اعمال دبی متغیر برای آبپاش‌ها، یک تصاعد هندسی فرضی بین دبی آنها در نظر گرفته شد. نتایج نشان داد اگر چه میزان فشار ورودی به لوله فرعی وابسته به میزان افت فشار موجود بین آبپاش‌ها می‌باشد، اما مقدار این وابستگی برای حالتی که بیش از 15 آبپاش روی لوله فرعی قرار گرفته باشند، قابل صرف‌نظر کردن است. نتایج هم‌چنین نشان داد برای حالتی که تعداد آبپاش‌ها کمتر از 15 عدد و نسبت فاصله اولین آبپاش از دهانه ورودی به فاصله آبپاش‌ها از همدیگر کمتر از 1 باشد، محاسبه فشار ابتدایی لوله با استفاده از روش‌های قبلی با خطا همراه است و بیشتر از مقدار واقعی تخمین زده می‌شود. در این تحقیق، معادله‌ای جدید برای محاسبه ضریب کریستین‌سن در حالتی که فاصله اولین آبپاش از ابتدای لوله، کسری از فاصله آبپاش‌ها است، به دست آمد. این ضریب علاوه بر تعداد آبپاش‌ها و توان پارامتر سرعت در معادله افت، به افت فشار موجود بین دو آبپاش ابتدا و انتهای لوله نیز وابسته است. برای حالتی که تعداد زیادی خروجی روی لوله فرعی قرار دارد، نتایج کاربرد معادله جدید این ضریب، همخوانی بسیار نزدیکی با نتایج عددی سایر محققین دارد</abstract_fa>
	<abstract>Precise calculation of inlet pressure into sprinkler laterals is an important problem for proper distribution of uniformity. The adjusted average friction correction factor, FaAVG , provides the possibility of calculating the inlet pressure to mutli-outlet pressurized irrigation pipelines when the first outlet spacing from the pipe entrance is arbitrary. To investigate the effect of allowable head-loss in the lateral pipeline on inlet pressure, a new equation was developed for calculating this factor. A progression coefficient was assumed for variable discharge of the outlets. The results showed that though the inlet pressure of the lateral depends on the head loss between the outlets, it is negligible when more than 15 outlets are used. It was also concluded that when N is less than 15 and the ratio of distance between inlet and first outlet to outlet spacing is less than 1, the conventional approaches overestimate the inlet pressure. In this research, a new equation was also developed for Christiansen friction factor in which the first outlet is located at a fraction of outlet spacing. This new factor is dependent on the head loss between the first and last outlets, in addition to the number of outlets and the power of velocity equation. The results of applying this new factor showed good correlation with other researchers’ numerical results when a large number of outlets are coalesced.</abstract>
	<keyword_fa>افت اصطکاک، ضریب کریستین‌سن، لوله فرعی، آبیاری بارانی</keyword_fa>
	<keyword>Friction loss, Christiansen factor, Lateral, Sprinkler irrigation.</keyword>
	<start_page>71</start_page>
	<end_page>79</end_page>
	<web_url>http://jstnar.iut.ac.ir/browse.php?a_code=A-10-10-8&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name>S. H. Sadeghi</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>سید حسین صادقی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name>S. F. Mousavi</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>سید فرهاد موسوی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mousavi@cc.iut .ac.ir</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name>M. Heidarpour</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>منوچهر حیدرپور</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
