<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Water and Soil Science</title>
<title_fa>علوم آب و خاک</title_fa>
<short_title>jwss</short_title>
<subject>Agriculture</subject>
<web_url>http://jstnar.iut.ac.ir</web_url>
<journal_hbi_system_id>0</journal_hbi_system_id>
<journal_hbi_system_user>user</journal_hbi_system_user>
<journal_id_issn>2476-3594</journal_id_issn>
<journal_id_issn_online>2476-5554</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.47176/jwss</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1393</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2014</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<volume>18</volume>
<number>67</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی آزمایشگاهی اثر شیب آبراهه و قطر میله روی ضریب تخلیه آبگیر با کف مشبک</title_fa>
	<title>Laboratory Study of Channel Slope and Rod Diameter Effect on Intake Discharge Coefficient under Rack Floor Condition</title>
	<subject_fa>عمومی</subject_fa>
	<subject>Ggeneral</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>یکی از گزینه‌های مناسب برای انحراف جریان در رودخانه‌های کوهستانی، به کارگیری آبگیر کفی است. از مهم‌ترین اهداف در جریان برروی یک آبگیر با کف مشبک، تعیین مقدار دبی منحرف شده در شرایط مختلف جریان در کانال اصلی است. شیب و شکل میله کف‌های مشبک بر میزان دبی منحرف شده تأثیر دارد. در این مقاله به بررسی شیب و نحوه قرارگیری میله مشبک آبگیر و اثر آن بر پارامترهای هیدرولیکی و ضریب تخلیه پرداخته شده است. به منظور انجام آزمایش در این تحقیق از یک مدل فیزیکی کانال اصلی با شیب متغیر و بدنه شیشه‌ای استفاده شد. به منظور هدایت و اندازه‌گیری دبی منحرف شده، یک کانال فرعی به فاصله 8 متری از ورودی کانال اصلی، در زیر کانال اصلی نصب گردید. دهانه آبگیر ورودی با طول 10 و عرض50 سانتی‌متر ساخته شد. در مدخل ورودی آبگیر از شبکه مشبک طولی با چهار قطر مختلف میلگرد با فضای عبوری ثابت و چهار شیب متفاوت استفاده شد. همچنین به منظور بررسی اثر شدت جریان در میزان آبگیری از چهار دبی استفاده گردید. نتایج این تحقیق نشان داد افزایش قطر میلگردهای کف مشبک، کاهش شیب کف آبراهه و افزایش عمق جریان در بالادست شبکه در یک فضای عبوری ثابت باعث افزایش در ضریب تخلیه آبگیر کفی می‌گردد. همچنین در تمام حالات افزایش عدد فرود در بالادست شبکه مشبک طولی، باعث کاهش ضریب تخلیه آبگیر می‌گردد.</abstract_fa>
	<abstract>Floor intake is one of the best options for diverting mountain rivers&#039; flow. Determination of discharge diverted in different conditions of flow in main channel is one of the main objectives for intake under rack floor condition. Gradient and shape of grid rod floor can affect the discharge deviated. In this experiment, placement and gradient of grid rods and also their effects on the discharge coefficient and hydraulic parameters were investigated. For this purpose, a physical model made of glass with variable gradient was used for the main channel. To conduct and measure the discharge diverted, a sub-channel 8 meters away from the entrance of main channel was installed below the main channel. Length and width of intake entrance were 10 and 50 cm, respectively. At the entrance of intake a longitudinal grid with four different rod diameters, constant-space passing, and four different gradients were used. Meanwhile, for the investigation of flow rate four discharges were used. The results showed that intake discharge coefficient was increased with an increase in diameter of grid rod floor, reduction in floor gradient, and increasing of depth in the upstream network. In all cases, increasing the Froude number resulted in an increase in the intake discharge coefficient in the upstream network</abstract>
	<keyword_fa>آبگیر کفی, قطر میلگرد, ضریب تخلیه, فضای عبوری, شیب کف مشبک </keyword_fa>
	<keyword>Floor intake, Rods diameter, Discharge coefficient, Flume floor slope.</keyword>
	<start_page>301</start_page>
	<end_page>308</end_page>
	<web_url>http://jstnar.iut.ac.ir/browse.php?a_code=A-10-565-5&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name>A. Masjedi</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>علیرضا مسجدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>drmasjedi.2007@yahoo.com</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name>A. Taeedi</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>امیر تائیدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
